Industrial chillers with an outstanding range of functions

Process chillers, sometimes referred to as circulating chillers, or recirculating water chillers, are primarily aimed at heat-removal from a heat-generating process. Their location varies from indoor usage to outdoor usage so they must be able to deal with varying weather conditions such as ambient temperatures extremes, to rainfall and snowfall.

Cooling requirements can range from a few Kilowatts of heat removal to several hundred Kilowatts, depending upon the application. If the unit is placed in a remote location, then it will be necessary to have some way of communicating remotely with the process chiller for the purposes of remote start/stop, parameter changes or fault diagnosis, as it may not always be practical to gain access to the chiller location quickly.

The LAUDA range of chillers lend themselves very well to the variety of applications and environments, whilst providing a robust and power-efficient solution.

Suitable for heat removal across the following application types: 

  • Net-zero applications - hydrogen electrolysers, dryers, methane-cracking (pyrolysis)
  • Laser / welding cooling applications
  • CNC and other machinery tooling cooling
  • Injection moulding cooling (plastics / composites)
  • Pump / compressor cooling
  • Cooling water supply for laboratories
  • Digital Printing press cooling
  • Brewing, distillery and food equipment cooling
  • Data centre cooling

Fields of application for industrial chillers

Circulation chillers for digital printing machines Circulation chillers for digital printing machines
Digital printing machines
Circulation chillers for laser cutting machines Circulation chillers for laser cutting machines
Laser cutting machines
Circulation chillers for laser sorting machines Circulation chillers for laser sorting machines
Laser sorting machines (food and recycling industry)
Circulation chillers for spot welding machines Circulation chillers for spot welding machines
Spot welding machines, CNC machines
Circulation chillers for induction heating system Circulation chillers for induction heating system
Induction heating systems
Circulation chillers for UV coating (printing industry) Circulation chillers for UV coating (printing industry)
UV coating (printing industry)
Circulation chillers for packaging machines (food industry) Circulation chillers for packaging machines (food industry)
Packaging machines (food industry)
Circulation chillers for hydrogen generators Circulation chillers for hydrogen generators
Hydrogen generators

WANT TO KNOW MORE?

Then get in touch with us for further information such as pricing and availability!

To the product inquiry

Industrial chillers in operation

Key specifications (some models may differ slightly)

Feature Benefit
Cooling power range from 3.1kW to 336kW at 20 Celsius Large cooling capability even for the most demanding applications (Note we supply custom design solutions beyond this capability also)
Operating range from -10 to 35 Celsius A large operating setpoint range to suit a diverse set of applications with an accuracy of +/- 0.5 Celsius
Operating ambient from -15 to 50 Celsius Suited to the extremes of ambient temperature expected in our region of the world
Energy-efficient design (compliant with Ecodesign Directive 2009/125/EC) Significant cost-saving on energy bills, reducing total cost of ownership
Pump pressures up to 6.9 bar Ability to cope with large pressure drops across the application or long piping distances to the application
Protection class up to IP54 rating for outdoor installation Ability to run trouble-free in outdoor environments when located according to the recommendations
Ethernet connectivity for remote communications Ability to run and monitor the process chiller from a remote location such as office, or on the go via a mobile phone or tablet

INTERESTED?

Write us an email for quick contact with our experts.

Quick email inquiry

Energy-efficient cooling. Future-proof to the maximum.

Cookies must be enabled to activate the embedded video. By activating them, data is transmitted to the respective provider. Further information can be found in our privacy policy.
Open cookie settings

LAUDA Ultracool: Energy efficiency comes first

High energy saving and a short payback time 
Depending on the operating conditions, the new circulation chillers are significantly more energy-efficient than conventional circulation chillers which are not Ecodesign-compliant.

A modern chiller that conforms with the EU Directive has clear advantages over older devices or products still in use and available outside the EU, which are not subject to the Directive. Some chillers exceed the required SEPR values for energy efficiency by some distance, such as the new generation of LAUDA Ultracool circulation chillers, which meet ecodesign requirements and incorporate a speed-controlled compressor, ventilator fan and electronic expansion valve.


Compliant with the Ecodesign Directive
The new LAUDA Ultracool circulation chillers comply with the Ecodesign Directive 2009/125/EC. This defines the limit values for energy efficiency that process circulation chillers must fulfill.


Short amortization times
The higher purchase price of an energy-efficient chiller, compared to a conventional device, typically amortizes between 1.5 and 2.5 years, thanks to savings made from reduced energy requirements.

The customer can determine the amortization time of a modern, energy-saving circulation chiller compared to conventional devices already in operation based on calculated energy savings, lower water/glycol costs, a tank content reduced by up to 80 percent and the lower maintenance costs of the new device.

The degree of chiller utilization is decisive in determining the amount of energy saved. The energy savings clearly demonstrate the efficiency of the new Ultracool model types from LAUDA.

Learn more now: Ultracool Whitepaper

Download our free white paper directly! In it, you will learn why our new process circulation chillers are also beneficial for your application.

Connectivity: Simplest network integration

User controls recirculating cooler via a tablet
The LAUDA Cloud: Clearly structured dashboards and KPIs facilitate monitoring and analysis

Optimized for Industry 4.0 
The new process circulation chillers are equipped with an LCD remote control as standard. An Ethernet interface for connection to a computer or local network (LAN) is also integrated as standard. In addition, the Ultracool devices can be controlled by means of a web server via a PC or even mobile devices - an internet connection is not necessary. All you need to do is to configure an IP address for the circulation chiller, which must be in the same network as the terminal device. The LAUDA Cloud enables monitoring and analysis of the device from any computer with an Internet connection – irrespective of location.

1. LCD remote control

  • Complete function control
  • Ergonomic and user-friendly
  • Cable connection with a length of 5 m

2. Internal web server

  • Connection to a computer or internal network (LAN)
  • Complete function control
  • Data logging/export for service and analysis
  • Possibility of data acquisition
  • No Internet connection necessary

3. LAUDA Cloud

  • New options for monitoring and control
  • Storage and evaluation of numerous device parameters
  • Remote maintenance minimizes costs and maximizes service efficiency
  • Complete functionality on all devices (desktop and notebook computers, smartphones, tablets) and all popular web browsers
  • Flexible connection to the cloud – 4G mobile communication via gateway
  • Continuous expansion of the LAUDA Cloud and its digital services, particularly of preventative and predictive maintenance through the use of artificial intelligence/ machine learning
  • Multi-level access control and state-of-the-art cloud security (e.g. two-factor authentication)
User stands next to chiller and operates it with the tablet
Simple operation: Extensive connectivity offers full control via control systems and mobile devices

Do you have questions?

Puneet Chavan
Sales Manager UK & Ireland

+44 1780 243118
E-Mail

There are already three products on your comparison list.
To compare other products, please delete one of the products on your comparison list.