Process cooling systems

Cooling systems from -100 to 150 °C

Heating and cooling systems from the process cooling unit line of the type series SUK always consist of the modules compressor, pump, expansion vessel, evaporator and condenser. Depending on the lowest working temperature, single stage (down to -35 °C) or two stage compressors (down to -50 °C) are used. At very low temperatures down to -100 °C, two cooling systems in cascade connection

are used. Cooling of the refrigerant condenser is done with cooling water or air. Output is regulated infinitely and precisely by injection control. If several compressors are used, an incremental switch ensures energy-saving, low-wear, partial load operation

(automatic compressor control). With an electric heater or steam-heated heat exchanger, the SUK type series can be used for temperatures from -100 to 150 °C. Pre-cooling with on-site brine or air can be easily implemented using the modular system. The application alone decides whether or not a cold accumulator is beneficial.

Multiple process cooling units in an industrial room.

TECHNICAL DATA FOR LAUDA PROCESS COOLING UNITS

Features SUK 150 W/L(Ex) SUK 250 W/L(Ex) SUK 350 W/L(Ex) SUK 400 W/L(Ex) SUK 600 W/L(Ex) SUK 1000 W/L(Ex)
Heat carriers Water, water/glycol, thermal oil, special liquids
Working temperature (°C) - 40 ... 150 - 50 ... 150 - 70 ... 150 - 100 ... 150 - 100 ... 150 - 100 ... 150
Pump output (m³/h) 0,5 … 2 2 … 6 2 ... 20 4 ... 30 5 ... 50 10 ... 80
Heating output (kW) up to 9 up to 18 up to 50 up to 60 up to 120 up to 240
Single-stage compressor
Cooling output at 20 °C (kW) up to10 up to 20 up to50 up to 150 up to 300 up to400
Cooling output at 0 °C (kW) up to 5 up to 15 up to 35 up to 120 up to 240 up to 300
Cooling output at - 20 °C (kW) up to 3 up to 6 up to 18 up to 60 up to 120 up to 180
Cooling output at - 40 °C (kW) up to 1 up to 2 up to 7 up to 45 up to 90 up to 120
Two-stage compressor
Cooling output at - 50 °C (kW) up to 1 up to 4 up to 35 up to 70 up to 90
Two-circuit cascade
Cooling output at - 60 °C (kW) up to 3 up to 25 up to 50 up to 70
Cooling output at - 70 °C (kW) up to 2 up to 10 up to 20 up to 35
Cooling output at - 80 °C (kW) up to 0.5 up to 5 up to 10 up to 20
Min. dimension (mm) 400 x 800 x 1000 500 x 1000 x 1500 800 x 1700 x 1500 1000 x 1500 x 1900 1500 x 2200 x 2000 1500 x 2200 x 2000
Max. dimension (mm) 500 x 1000 x 1500 600 x 1500 x 1500 1000 x 1500 x 1900 1300 x 1900 x 2000 200 x 2500 x 2000 2000 x 2500 x 2000
Features KH 150 W/L(Ex) KH 250 W/L(Ex) KH 350 W/L(Ex) KH 400 W/L(Ex) KH 600 W/L(Ex) KH 1000 W/L(Ex)
Heat carriers Thermal oil, special liquids
Working temperature (°C) - 40 ... 250 - 50 ... 250 - 70 ... 250 - 100 ... 250 - 100 ... 250 - 100 ... 400
Pump output (m³/h) 0.5 … 2 2 … 6 2 ... 20 4 ... 30 5 ... 50 10 ... 80
Heating output (kW) up to 9 up to 18 up to 50 up to 60 up to 120 up to 240
Single-stage compressor
Cooling output at 20 °C (kW) up to10 up to20 up to50 up to150 up to300 up to400
Cooling output at 0 °C (kW) up to 5 up to 15 up to 35 up to 120 up to 240 up to 300
Cooling output at - 20 °C (kW) up to 3 up to 6 up to 18 up to 60 up to 120 up to 180
Cooling output at - 40 °C (kW) up to 1 up to 2 up to 7 up to 45 up to 90 up to 120
Two-stage compressor
Cooling output at - 50 °C (kW) up to 1 up to 4 up to 35 up to 70 up to 90
Two-circuit cascade
Cooling output at - 60 °C (kW) up to 3 up to 25 up to 50 up to 70
Cooling output at - 70 °C (kW) up to 2 up to 10 up to 20 up to 35
Cooling output at - 80 °C (kW) up to 0.5 up to 5 up to 10 up to 20
Min. dimension (mm) 500 x 800 x 1000 600 x 1000 x 1500 800 x 1700 x 1500 1000 x 1500 x 1900 1500 x 2200 x 2000 1500 x 2200 x 2000
Max. dimension (mm) 600 x 1000 x 1500 800 x 1700 x 1500 1000 x 1500 x 1900 1300 x 1900 x 2000 2000 x 2500 x 2000 2000 x 2500 x 2000

Your advantages at a glance

Digital temperature controllers

for the control of consumers/product temperature, as well as outflow temperature

Energy-efficient cooling system with high dynamic

Thanks to modern refrigeration modules for the best possible configuration of compressor and output

Automatic shut-off valve in the cooling water inflow

To prevent contamination of the heat exchanger

Hermetic model without gaskets

So that oil and water are not mixed

Infinitely controlled electrical stainless steel heating bodies

This way, the heating output can be adapted to the actual energy requirement

FAT (Factory Acceptance Test) in the customer's presence

For checking that the systems are designed for customer requirements and initial training and test run even before delivery

Fields of expertise

Heat transfer unitHeat transfer unit
Heat transfer systems
Process cooling unitsProcess cooling units
Process cooling systems
Secondary circuit unitsSecondary circuit units
Secondary circuit systems
Kryopac systemKryopac system
Kryopac
Molten salt plantMolten salt plant
Molten salt plants
Gas-fired heaterGas-fired heater
Gas fired heaters