HEAT TRANSFER SYSTEMS

Universal systems up to 400 °C

Depending on the required outflow temperature, heat transfer units use either thermal oil, water or water/glycol as the heat carrier. They are electrically heated and generate a temperature-controlled liquid flow. Heating and cooling systems in the heat transfer unit line always consist of the electric heater module and a maximum of one additional heat exchanger module (cooler). In this version, or in combination with a process cooling unit, a heating and cooling system is created with an extended working temperature range.

Eine Wärmeübertragungsanlage in einem Industrieraum.

TECHNICAL DATA FOR LAUDA HEAT TRANSFER UNITS

Features ITH 150 ITH 250 ITH 350 ITH 400 ITH 600
Heat carriers Thermal oil
Working temperature (°C) max. 400
Pump output (m³/h) 0,5 … 2 2 … 4 4 … 10 10 … 30 30 … 80
Heating output (kW) 3 ... 6 9 ... 12 18 ... 50 60 ... 100 125 ... 500
Cooling Water, brine or air-cooled heat exchangers
Min. dimension (mm) 500 x 800 x 1000 500 x 1000 x 1200 600 x 1000 x 1500 600 x 1500 x 1500 1000 x 1500 x 1900
Max. dimension (mm) 600 x 1500 x 1500 1000 x 1500 x 1900 1300 x 1900 x 2000
Features ITHW 150 ITHW 250 ITHW 350 ITHW 400 ITHW 600
Heat carriers Water, water/glycol
Working temperature (°C) max. 200
Pump output (m³/h) 0,5 … 2 2 … 4 4 … 10 10 … 30 30 … 80
Heating output (kW) 6 ... 12 18 ... 24 30 ... 50 60 ... 100 125 ... 500
Cooling Water, brine or air-cooled heat exchangers
Min. dimension (mm) 400 x 800 x 1000 500 x 1000 x 1500 500 x 1000 x 1500 600 x 1500 x 1800 1000 x 1500 x 1900
Max. dimension (mm) 600 x 1500 x 1500 1000 x 1500 x 1900 1300 x 1900 x 2000

Your advantages at a glance

Digital temperature controllers

for the control of consumers/product temperature, as well as outflow temperature

Infinitely controlled electrical stainless steel heating bodies

So that the heating output is adjusted to the actual energy requirements and a long service life of the thermal oil and heating elements is guaranteed

Automatic shut-off valve in the cooling water inflow

To prevent contamination of the heat exchanger

Hermetic model without gaskets

So that oil and water are not mixed

Simple replacement of the heat exchanger

With water, brine or air-cooled stainless steel plate-heat exchanger and tubular heat exchanger in a flange model

FAT (Factory Acceptance Test) in the customer's presence

For checking that the systems are designed for customer requirements and initial training and test run even before delivery

Fields of expertise

Heat transfer unitHeat transfer unit
Heat transfer systems
Process cooling unitsProcess cooling units
Process cooling systems
Secondary circuit unitsSecondary circuit units
Secondary circuit systems
Kryopac systemKryopac system
Kryopac
Molten salt plantMolten salt plant
Molten salt plants
Gas-fired heaterGas-fired heater
Gas fired heaters

Do you have any questions?

Kirstin Schmitt
Inside Sales

+49 9343 503-167
E-Mail

There are already three products on your comparison list.
To compare other products, please delete one of the products on your comparison list.